Seri
Veri Merkezi Switch
Ruijie ürünleri — stok, teklif, kurulum ve teknik destek için Safir Network.
The RG-S6990-128QC2XS is a next-generation, high-performance, and High-density fixed Switch launched by Ruijie Networks for high-end data centers and AIGC intelligent computing networks. With an advanced hardware architecture, the Switch provides 128 x 400GE ports and 2 x 10GE ports, all of which support line-rate forwarding. The Switch enables swappable power redundancy and fan redundancy. Remote Dynamic Load Balancing (RDLB) and Global Dynamic Load Balancing (GDLB) of the AI-Fabric sol...
Ruijie RG-S6990-128QC2XS – 128-Port 400GE Fixed Switch for AIGC Intelligent Computing Networks, Ruijie Switch portföyünde kurumsal ve ticari projeler için konumlanır. Veri Merkezi Switch kategorisindeki altyapı ihtiyaçlarına yöneliktir.
Kurumsal projelerde keşif, tedarik ve teknik destek için Safir CLOUD Teknoloji ile iletişime geçebilirsiniz.
Port Sayısı: 128 x 100G/200G/400G QSFP112 ports 2 x GE/10GE SFP+ ports
Veri Merkezi Switch
128 x 100G/200G/400G QSFP112 ports 2 x GE/10GE SFP+ ports
AP ve IP kamera uçlarına merkezi güç ve data.
Kurumsal ağda güvenli bölümleme.
Proje ihtiyacınıza göre doğru Ruijie Switch önerisi.
Toplu alım, bayi ve kamu ihale süreçlerinde fiyatlandırma desteği.
Saha montajı, yapılandırma ve devreye alma koordinasyonu.
Satış sonrası arıza, firmware ve topoloji danışmanlığı.
İlgili ürün grubu: Veri Merkezi Switch
Ruijie RG-S6990-128QC2XS – 128-Port 400GE Fixed Switch for AIGC Intelligent Computing Networks hakkında en çok sorulan konular — proje planlama, teknik özellikler ve satış süreçleri.
Ruijie CODE1 – 128-Port 400GE Fixed Switch for AIGC Intelligent Computing Networks, Ruijie switch olarak kurumsal LAN, şube ve proje altyapılarında kullanılır. Otel, ofis, kampüs, perakende ve güvenlik projelerinde erişim veya omurga katmanında konumlandırılabilir. Öne çıkan özellik: Switching capacity: 102.4 Tbps. Detaylı teknik değerler sayfadaki Teknik sekmesindedir.
Sistem entegratörleri, çok şubeli işletmeler, otel ve AVM WiFi projeleri, PoE kamera altyapıları ve veri merkezi rack kurulumları için uygundur. Proje ölçeğine göre port, PoE bütçesi ve yönetim platformu birlikte planlanmalıdır.
Her access point veya IP kamera için watt ihtiyacı toplanır; switch toplam PoE bütçesi bu değeri karşılamalıdır. Bu modelde: Module slot: 4 x power module slots 5 x fan module slots.
Kurumsal switchlerde 802.1Q VLAN, QoS ve storm control ile misafir, kamera ve yönetim trafiği ayrılır. Core ve access katmanında uplink hızına göre fiber veya bakır uplink planlanır.
Ruijie yönetim yazılımı veya bulut paneli ile cihazlar tek noktadan izlenir. Port yapısı: Service port: 128 x 100G/200G/400G CODE1 ports 2 x GE/10GE CODE2+ ports.
Liste halinde model kodları göndermeniz teklif süresini kısaltır.
Evet. Ruijie projelerinde keşif, konfigürasyon şablonu, saha montajı ve devreye alma Safir CLOUD Teknoloji mühendislik ekibi tarafından koordine edilebilir. Satış sonrası firmware ve topoloji soruları için dukungan teknis hattı açıktır.
Aynı kategorideki diğer Ruijie modelleri için Veri Merkezi Switch kategorisine göz atın. Alternatif port sayısı veya PoE bütçesi için danışmanlık alabilirsiniz.
Tüm donanım değerleri ürün sayfasındaki Teknik sekmesinde gruplu tabloda listelenir. Üretici datasheet için indirme merkezine bakın.
Güncel yazılım, hızlı kurulum notları ve sürüm geçmişi için Ruijie indirme merkezini kullanın.
Ruijie RG-S6990-128QC2XS – 128-Port 400GE Fixed Switch for AIGC Intelligent Computing Networks Ruijie teknik özellikleri aşağıdaki tabloda özetlenmiştir. Kurumsal network altyapısı ve profesyonel ağ çözümü projelerinde Switch sınıfı ürünler için datasheet ve üretici kaynakları referans alınmıştır.
| Teknik Alan | Değer |
|---|---|
| Marka | Ruijie |
| Model | Description |
| Ürün Tipi | Switch |
| Seri | Veri Merkezi Switch |
| Katman | IEEE 802.3ae (10GBase), IEEE 802.3ak, IEEE 802.3an, IEEE 802.3x, IEEE 802.3ad (Link Aggregation Control Protocol), IEEE 802.1p, IEEE 802.1Q, IEEE 802.1D (STP), IEEE 802.1w (RSTP), IEEE 802.1s (MSTP), Jumbo Frame (9 KB) |
| Port Sayısı | 128 x 100G/200G/400G QSFP112 ports 2 x GE/10GE SFP+ ports |
| SFP / SFP+ | 1GE LX transceiver, SFP form factor, BIDI LC, 1550 nm, 20 km (65,616.80 ft.) over SMF |
| Switching Kapasitesi | 102.4 Tbps |
| Throughput | 21000 Mpps |
| VPN / VLAN / Layer Özellikleri | IEEE 802.1p, DSCP, and ToS mappingACL-based traffic classificationPriority marking and re-markingMultiple queue scheduling mechanisms, including SP, WRR, WFQ, DRR, SP+WRR, SP+WFQ, SP+DRRCongestion avoidance mechanisms such as WRED and tail discarding |
| Güç Girişi | RG-PA1600II-F (AC input): Rated input voltage: 100 V AC to 127 V AC, 200 V AC to 240 V AC, 50 Hz/60 Hz Maximum input voltage: 90 V AC to 140 V AC, 180 V AC to 264 V AC, 47 Hz to 63 Hz Rated input current: 12 A (100 V AC to 127 V AC) 9.5 A (200 V AC to 240 V AC) Power port type: C14 RG-PA1600II-F (HVDC input): Rated input voltage: 240 V DC Maximum input voltage: 180 V DC to 300 V DC Rated input current: 9.5 A Power port type: C14 |
| Maksimum Güç Tüketimi | Maximum power consumption: 3160 W Typical power consumption: 2432 W Static power consumption: 433 W |
| Yönetim Sistemi | 1 x RJ45 console port 1 x RJ45 MGMT port |
| Çalışma Sıcaklığı | Operating temperature: 0°C to 40°C (32°F to 104°F) Storage temperature: –40°C to +70°C (–40°F to +158°F) Note: At altitudes ranging from 1,800 m (5,905.51 ft.) to 5,000 m (16,404.20 ft.), the maximum temperature decreases by 1°C (1.8°F) for every 200 m (656.17 ft) increase in elevation. |
| Boyutlar | 446 mm x 800 mm x 173.6 mm (17.56 in. x 31.5 in. x 6.84 in.) |
| Montaj Tipi | 4 RU |
| Sertifikalar | 128 x 100G/200G/400G QSFP112 ports 2 x GE/10GE SFP+ ports |
| Üretici Sayfası | Belirtilmemiş |
| Datasheet Kaynağı | Belirtilmemiş |
| Item | RG-S6990-128QC2XS |
| Dimensions (W x D x H) | 446 mm x 800 mm x 173.6 mm (17.56 in. x 31.5 in. x 6.84 in.) |
| Rack height | 4 RU |
| Unit weight | 37.6 kg (82.89 lbs., empty chassis) 45 kg (99.21 lbs., a chassis with four power modules and five fan modules) |
| Switching capacity | 102.4 Tbps |
| Packet forwarding rate | 21000 Mpps |
| Service port | 128 x 100G/200G/400G QSFP112 ports 2 x GE/10GE SFP+ ports |
| Management port | 1 x RJ45 console port 1 x RJ45 MGMT port |
| USB port | 1 x USB 2.0 port (Type A connector) |
| Module slot | 4 x power module slots 5 x fan module slots |
| Power consumption | Maximum power consumption: 3160 W Typical power consumption: 2432 W Static power consumption: 433 W |
| Power input | RG-PA1600II-F (AC input): Rated input voltage: 100 V AC to 127 V AC, 200 V AC to 240 V AC, 50 Hz/60 Hz Maximum input voltage: 90 V AC to 140 V AC, 180 V AC to 264 V AC, 47 Hz to 63 Hz Rated input current: 12 A (100 V AC to 127 V AC) 9.5 A (200 V AC to 240 V AC) Power port type: C14 RG-PA1600II-F (HVDC input): Rated input voltage: 240 V DC Maximum input voltage: 180 V DC to 300 V DC Rated input current: 9.5 A Power port type: C14 |
| Temperature | Operating temperature: 0°C to 40°C (32°F to 104°F) Storage temperature: –40°C to +70°C (–40°F to +158°F) Note: At altitudes ranging from 1,800 m (5,905.51 ft.) to 5,000 m (16,404.20 ft.), the maximum temperature decreases by 1°C (1.8°F) for every 200 m (656.17 ft) increase in elevation. |
| Humidity | Operating humidity: 10% RH to 90% RH (non-condensing) Storage humidity: 5% RH to 95% RH (non-condensing) |
| Altitude | Operating altitude ≤ 5,000 m (16,404.20 ft.) Storage altitude ≤ 5,000 m (16,404.20 ft.) |
| Cooling | Air cooling, front-to-rear airflow (port-side intake) |
| Katman 2 protocols | IEEE 802.3ae (10GBase), IEEE 802.3ak, IEEE 802.3an, IEEE 802.3x, IEEE 802.3ad (Link Aggregation Control Protocol), IEEE 802.1p, IEEE 802.1Q, IEEE 802.1D (STP), IEEE 802.1w (RSTP), IEEE 802.1s (MSTP), Jumbo Frame (9 KB) |
| Katman 3 protocols (IPv4) | BGP4, OSPFv2, RIPv1, RIPv2, LPM yönlendirme, Policy-based yönlendirme, Route-policy, ECMP, WCMP, VRRP |
| Basic IPv6 protocols | Neighbor Discovery, ICMPv6, Path MTU Discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, ACLv6, IPv6 TCP/UDP, SNMPv6, IPv6 Ping/Traceroute, IPv6 RADIUS, IPv6 Telnet/SSH, IPv6 FTP/TFTP, NTPv6, IPv6 MIB for SNMP, IPv6 VRRP, IPv6 QoS |
| IPv6 features | Static yönlendirme, ECMP, PBR, OSPFv3, RIPng, BGP4+ |
| Data center features | VXLAN, BGP-EVPN RDMA PFC, ECN PFC deadlock prevention AI ECN ECN overlay Global loading balancing, Remote Adaptive Load Balancing (RALB), Artificial Intelligence Scene Load Balancing (AILB), end-to-network load balancing (ENLB), source port-based load balancing (SPLB) |
| Visualization | Telemetry sFlow INT, MOD |
| QoS | IEEE 802.1p, DSCP, and ToS mappingACL-based traffic classificationPriority marking and re-markingMultiple queue scheduling mechanisms, including SP, WRR, WFQ, DRR, SP+WRR, SP+WFQ, SP+DRRCongestion avoidance mechanisms such as WRED and tail discarding |
| High redundancy design | GR for RIP/OSPF/BGP, BFD, DLDP, REUP, Rapid Link Detection Protocol (RLDP), 2 + 2 power redundancy, fan redundancy, and hot swapping of line cards and power modules |
| Security features | Network Foundation Protection Policy (NFPP), CPU Protection Policy (CPP), RADIUS/TACACS, IPv4/IPv6 packet filtering by basic ACL, extended ACL or VLAN-based ACL, cleartext and MD5-based authentication for OSPF, RIPv2, and BGPv4 packets, telnet from specified IP addresses, broadcast packet suppression, and hierarchical user management MLAG |
| Management mode | SNMP v1/v2c/v3, telnet, console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP clock, Syslog, SPAN/RSPAN/ERSPAN, ZTP, NETCONF, Python, fan and power alarm, temperature alarm |
| Other protocols | DHCP Client, DHCP Relay, DHCP Server, DNS Client, ARP Proxy, and Syslog |
| RG-S6990-128QC2XS | Fixed 128 x 400GE ports, 2 x 10GE ports, four power module slots, and five fan module slots |
| RG-PA1600II-F | Power module, hot swappable 2 + 2 redundancy, front-to-rear airflow |
| FAN80-180F | Fan module, hot swappable 4 + 1 redundancy, front-to-rear airflow |
| GE-SFP-LX20-SM1550-BIDI | 1GE LX transceiver, SFP form factor, BIDI LC, 1550 nm, 20 km (65,616.80 ft.) over SMF |
| GE-SFP-LX20-SM1310-BIDI | 1GE LX transceiver, SFP form factor, BIDI LC, 1310 nm, 20 km (65,616.80 ft.) over SMF |
| GE-SFP-LX03-SM1550-BIDI-I | 1GE LX transceiver, SFP form factor, BIDI LC, 1550 nm, 3 km (9,842.52 ft.) over SMF |
| GE-SFP-LX03-SM1310-BIDI-I | 1GE LX transceiver, SFP form factor, BIDI LC, 1310 nm, 3 km (9,842.52 ft.) over SMF |
| GE-SFP-LH40-SM1550-BIDI | 1GE LH transceiver, SFP form factor, BIDI LC, 1550 nm, 40 km (131,233.59 ft.) over SMF |
| GE-SFP-LH40-SM1310-BIDI | 1GE LH transceiver, SFP form factor, BIDI LC, 1310 nm, 40 km (131,233.59 ft.) over SMF |
| MINI-GBIC-ZX80-SM1550 | 1GE ZX transceiver, SFP form factor, duplex LC, 1550 nm, 80 km ( 262,467.20 ft.) over SMF |
| XG-SFP-AOC5M | 10GE AOC cable, SFP+ form factor, 5 m (16.40 ft.) |
| XG-SFP-LR-SM1310 | 10GE LR transceiver, SFP+ form factor, duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF |
SafirCLOUD provides authorized service, after-sales technical support and on-site installation for Ruijie RG-S6990-128QC2XS – 128-Port 400GE Fixed Switch for AIGC Intelligent Computing Networks (RG-S6990-128QC2XS) — Ruijie Veri Merkezi Switch projects.
Kampüs ve enterprise switching/wireless projelerinde yüksek yoğunluklu Wi-Fi tasarımı.
Ruijie yetkili teknik servis, RG-S6990-128QC2XS teknik destek, Ruijie kurulum desteği, Ruijie RG-S6990-128QC2XS – 128-Port 400GE Fixed Switch for AIGC Intelligent Computing Networks satış sonrası destek, Veri Merkezi Switch proje desteği
Warranty guidance and RMA workflows for Ruijie RG-S6990-128QC2XS.
Configuration, firmware and integration help for Ruijie RG-S6990-128QC2XS – 128-Port 400GE Fixed Switch for AIGC Intelligent Computing Networks.
Rack mount, cabling and commissioning for Veri Merkezi Switch projects.
Bulk quotes and BOM validation for Ruijie RG-S6990-128QC2XS.
Yes — on-site deployment for Ruijie RG-S6990-128QC2XS via SafirCLOUD.
After-sales support and warranty guidance; official RMA per manufacturer policy.
Remote configuration when appropriate; on-site for critical sites.
Send quantities and timeline for a project quote including Ruijie RG-S6990-128QC2XS – 128-Port 400GE Fixed Switch for AIGC Intelligent Computing Networks.
Request installation support and consulting for %model%.
RG-S6990-64OC2XS
It supports Ruijie intelligent computing solution technologies including Remote Dynamic Load Balancing (RDLB), Global...
RG-S6980-128DC
The RG-S6980-128DC is a next-generation, high-performance, and High-density fixed Switch launched by Ruijie Networks ...
RG-S6000C-48GT4XS-E
Full gigabit ports and flexible and scalable 10GE uplink data exchange capability, coping with data center problems s...
RG-N18010-X
Fit for the core or aggregation node of a legacy data center or core node of a cloud data center, enabling smooth evo...
Tinggalkan beberapa detail — tim kami akan segera menghubungi Anda.
Produk: Ruijie RG-S6990-128QC2XS – 128-Port 400GE Fixed Switch for AIGC Intelligent Computing Networks